Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
EJNMMI Phys ; 11(1): 25, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38472680

RESUMO

BACKGROUND: Accurate image-derived input function (IDIF) from highly sensitive large axial field of view (LAFOV) PET/CT scanners could avoid the need of invasive blood sampling for kinetic modelling. The aim is to validate the use of IDIF for two kinds of tracers, 3 different IDIF locations and 9 different reconstruction settings. METHODS: Eight [18F]FDG and 10 [18F]DPA-714 scans were acquired respectively during 70 and 60 min on the Vision Quadra PET/CT system. PET images were reconstructed using various reconstruction settings. IDIFs were taken from ascending aorta (AA), descending aorta (DA), and left ventricular cavity (LV). The calibration factor (CF) extracted from the comparison between the IDIFs and the manual blood samples as reference was used for IDIFs accuracy and precision assessment. To illustrate the effect of various calibrated-IDIFs on Patlak linearization for [18F]FDG and Logan linearization for [18F]DPA-714, the same target time-activity curves were applied for each calibrated-IDIF. RESULTS: For [18F]FDG, the accuracy and precision of the IDIFs were high (mean CF ≥ 0.82, SD ≤ 0.06). Compared to the striatum influx (Ki) extracted using calibrated AA IDIF with the updated European Association of Nuclear Medicine Research Ltd. standard reconstruction (EARL2), Ki mean differences were < 2% using the other calibrated IDIFs. For [18F]DPA714, high accuracy of the IDIFs was observed (mean CF ≥ 0.86) except using absolute scatter correction, DA and LV (respectively mean CF = 0.68, 0.47 and 0.44). However, the precision of the AA IDIFs was low (SD ≥ 0.10). Compared to the distribution volume (VT) in a frontal region obtained using calibrated continuous arterial sampler input function as reference, VT mean differences were small using calibrated AA IDIFs (for example VT mean difference = -5.3% using EARL2), but higher using calibrated DA and LV IDIFs (respectively + 12.5% and + 19.1%). CONCLUSIONS: For [18F]FDG, IDIF do not need calibration against manual blood samples. For [18F]DPA-714, AA IDIF can replace continuous arterial sampling for simplified kinetic quantification but only with calibration against arterial blood samples. The accuracy and precision of IDIF from LAFOV PET/CT system depend on tracer, reconstruction settings and IDIF VOI locations, warranting careful optimization.

2.
J Cereb Blood Flow Metab ; 43(3): 369-378, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36271598

RESUMO

Alzheimer's disease is characterized by regional reductions in cerebral blood flow (CBF). Although the gold standard for measuring CBF is [15O]H2O PET, proxies of relative CBF, derived from the early distribution phase of amyloid and tau tracers, have gained attention. The present study assessed precision of [15O]H2O derived relative and absolute CBF, and compared precision of these measures with that of (relative) CBF proxies. Dynamic [15O]H2O, [18F]florbetapir and [18F]flortaucipir PET test-retest (TrT) datasets with eleven, nine and fourteen subjects, respectively, were included. Analyses were performed using an arterial input model and/or a simplified reference tissue model, depending on the data available. Relative CBF values (i.e. K1/K1' and/or R1) were obtained using cerebellar cortex as reference tissue and TrT repeatability (i.e. precision) was calculated and compared between tracers, parameters and clinical groups. Relative CBF had significantly better TrT repeatability than absolute CBF derived from [15O]H2O (r = -0.53), while best TrT repeatability was observed for [18F]florbetapir and [18F]flortaucipir R1 (r = -0.23, r = -0.33). Furthermore, only R1 showed, better TrT repeatability for cognitively normal individuals. High precision of CBF proxies could be due to a compensatory effect of the extraction fraction, although changes in extraction fraction could also bias these proxies, but not the gold standard.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/metabolismo , Tomografia por Emissão de Pósitrons , Compostos de Anilina , Circulação Cerebrovascular/fisiologia , Encéfalo/metabolismo
3.
J Cereb Blood Flow Metab ; 41(6): 1338-1350, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34013797

RESUMO

[11C]UCB-J is a novel radioligand that binds to synaptic vesicle glycoprotein 2A (SV2A). The main objective of this study was to determine the 28-day test-retest repeatability (TRT) of quantitative [11C]UCB-J brain positron emission tomography (PET) imaging in Alzheimer's disease (AD) patients and healthy controls (HCs). Nine HCs and eight AD patients underwent two 60 min dynamic [11C]UCB-J PET scans with arterial sampling with an interval of 28 days. The optimal tracer kinetic model was assessed using the Akaike criteria (AIC). Micro-/macro-parameters such as tracer delivery (K1) and volume of distribution (VT) were estimated using the optimal model. Data were also analysed for simplified reference tissue model (SRTM) with centrum semi-ovale (white matter) as reference region. Based on AIC, both 1T2k_VB and 2T4k_VB described the [11C]UCB-J kinetics equally well. Analysis showed that whole-brain grey matter TRT for VT, DVR and SRTM BPND were -2.2% ± 8.5, 0.4% ± 12.0 and -8.0% ± 10.2, averaged over all subjects. [11C]UCB-J kinetics can be well described by a 1T2k_VB model, and a 60 min scan duration was sufficient to obtain reliable estimates for both plasma input and reference tissue models. TRT for VT, DVR and BPND was <15% (1SD) averaged over all subjects and indicates adequate quantitative repeatability of [11C]UCB-J PET.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Neuroimagem/métodos , Piridinas/farmacocinética , Pirrolidinonas/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/metabolismo , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Cinética , Masculino , Glicoproteínas de Membrana/metabolismo , Pessoa de Meia-Idade , Proteínas do Tecido Nervoso/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes
4.
J Cereb Blood Flow Metab ; 41(3): 569-578, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32321347

RESUMO

Accumulation of amyloid beta (Aß) is one of the pathological hallmarks of Alzheimer's disease (AD), which can be visualized using [18F]florbetapir positron emission tomography (PET). The aim of this study was to evaluate various parametric methods and to assess their test-retest (TRT) reliability. Two 90 min dynamic [18F]florbetapir PET scans, including arterial sampling, were acquired (n = 8 AD patient, n = 8 controls). The following parametric methods were used; (reference:cerebellum); Logan and spectral analysis (SA), receptor parametric mapping (RPM), simplified reference tissue model2 (SRTM2), reference Logan (rLogan) and standardized uptake value ratios (SUVr(50-70)). BPND+1, DVR, VT and SUVr were compared with corresponding estimates (VT or DVR) from the plasma input reversible two tissue compartmental (2T4k_VB) model with corresponding TRT values for 90-scan duration. RPM (r2 = 0.92; slope = 0.91), Logan (r2 = 0.95; slope = 0.84) and rLogan (r2 = 0.94; slope = 0.88), and SRTM2 (r2 = 0.91; slope = 0.83), SA (r2 = 0.91; slope = 0.88), SUVr (r2 = 0.84; slope = 1.16) correlated well with their 2T4k_VB counterparts. RPM (controls: 1%, AD: 3%), rLogan (controls: 1%, AD: 3%) and SUVr(50-70) (controls: 3%, AD: 8%) showed an excellent TRT reliability. In conclusion, most parametric methods showed excellent performance for [18F]florbetapir, but RPM and rLogan seem the methods of choice, combining the highest accuracy and best TRT reliability.


Assuntos
Doença de Alzheimer/diagnóstico , Compostos de Anilina/química , Etilenoglicóis/química , Compostos Radiofarmacêuticos/química , Idoso , Encéfalo/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Radioisótopos de Flúor/química , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons
5.
J Cereb Blood Flow Metab ; 40(12): 2464-2474, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31575335

RESUMO

The aim of this study was to investigate the test-retest (TRT) repeatability of various parametric quantification methods for [18F]Flortaucipir positron emission tomography (PET). We included eight subjects with dementia or mild cognitive impairment due to Alzheimer's disease and six cognitively normal subjects. All underwent two 130-min dynamic [18F]Flortaucipir PET scans within 3 ± 1 weeks. Data were analyzed using reference region models receptor parametric mapping (RPM), simplified reference tissue method 2 (SRTM2) and reference logan (RLogan), as well as standardized uptake value ratios (SUVr, time intervals 40-60, 80-100 and 110-130 min post-injection) with cerebellar gray matter as reference region. We obtained distribution volume ratio or SUVr, first for all brain regions and then in three tau-specific regions-of-interest (ROIs). TRT repeatability (%) was defined as |retest-test|/(average (test + retest)) × 100. For all methods and across ROIs, TRT repeatability ranged from (median (IQR)) 0.84% (0.68-2.15) to 6.84% (2.99-11.50). TRT repeatability was good for all reference methods used, although semi-quantitative models (i.e. SUVr) performed marginally worse than quantitative models, for instance TRT repeatability of RPM: 1.98% (0.78-3.58) vs. SUVr80-100: 3.05% (1.28-5.52), p < 0.001. Furthermore, for SUVr80-100 and SUVr110-130, with higher average SUVr, more variation was observed. In conclusion, while TRT repeatability was good for all models used, quantitative methods performed slightly better than semi-quantitative methods.


Assuntos
Doença de Alzheimer/metabolismo , Encéfalo/metabolismo , Carbolinas/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Idoso , Doença de Alzheimer/complicações , Doença de Alzheimer/diagnóstico por imagem , Peptídeos beta-Amiloides/metabolismo , Encéfalo/diagnóstico por imagem , Cognição/fisiologia , Disfunção Cognitiva/metabolismo , Feminino , Substância Cinzenta/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos/normas , Compostos Radiofarmacêuticos/metabolismo , Reprodutibilidade dos Testes , Proteínas tau/metabolismo
6.
J Cereb Blood Flow Metab ; 40(2): 365-373, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-30569813

RESUMO

[18F]Flortaucipir is a PET tau tracer used to visualize tau binding in Alzheimer's disease (AD) in vivo. The present study evaluated the performance of several methods to obtain parametric images of [18F]flortaucipir. One hundred and thirty minutes dynamic PET scans were performed in 10 AD patients and 10 controls. Parametric images were generated using different linearization and basis function approaches. Regional binding potential (BPND) and volume of distribution (VT) values obtained from the parametric images were compared with corresponding values derived using the reversible two-tissue compartment model (2T4k_VB). Performance of SUVr parametric images was assessed by comparing values with distribution volume ratio (DVR) and SRTM-derived BPND estimates obtained using non-linear regression (NLR). Spectral analysis (SA) (r2 = 0.92; slope = 0.99) derived VT correlated well with NLR-derived VT. RPM (r2 = 0.95; slope = 0.98) derived BPND correlated well with NLR-derived DVR. Although SUVr80-100 min correlated well with NLR-derived DVR (r2 = 0.91; slope = 1.09), bias in SUVr appeared to depend on uptake time and underlying level of specific binding. In conclusion, RPM and SA provide parametric images comparable to the NLR estimates. Individual SUVr values are biased compared with DVR and this bias requires further study in a larger dataset in order to understand its consequences.


Assuntos
Doença de Alzheimer , Encéfalo , Carbolinas , Tomografia por Emissão de Pósitrons , Proteínas tau/metabolismo , Idoso , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Carbolinas/administração & dosagem , Carbolinas/farmacocinética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Neuroimage Clin ; 25: 102113, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31835238

RESUMO

BACKGROUND: Off-target [18F]flortaucipir (tau) PET binding in the choroid plexus causes spill-in into the nearby hippocampus, which may influence the correlation between [18F]flortaucipir binding and measures of cognition. Previously, we showed that partial volume correction (combination of Van Cittert iterative deconvolution and HYPR denoising; PVC HDH) and manually eroding the hippocampus resulted in a significant decrease of the choroid plexus spill-in. In this study, we compared three different approaches for the quantification of hippocampal [18F]flortaucipir signal using a semi-automated technique, and assessed correlations with cognitive performance across methods. METHODS: Dynamic 130 min [18F]flortaucipir PET scans were performed in 109 subjects (45 cognitively normal subjects (CN) and 64 mild cognitive impairment/Alzheimer's disease (AD) dementia patients. We extracted hippocampal binding potential (BPND) using receptor parametric mapping with cerebellar grey matter as reference region. PVC HDH was performed. Based on our previous study in which we manually eroded 40% ± 10% of voxels of the hippocampus, three hippocampal volumes-of-interest (VOIs) were generated: a non-optimized 100% hippocampal VOI [100%], and combining HDH with eroding a percentage of the highest hippocampus BPND voxels (i.e. lowering spill-in) resulting in optimized 50%[50%HDH] and 40%[40%HDH] hippocampal VOIs. Cognitive performance was assessed with the Mini-Mental State Examination (MMSE) and Rey auditory verbal learning delayed recall. We performed receiver operating characteristic analyses to investigate which method could best discriminate MCI/AD from controls. Subsequently, we performed linear regressions to investigate associations between the hippocampal [18F]flortaucipir BPND VOIs and MMSE/delayed recall adjusted for age, sex and education. RESULTS: We found higher hippocampal [18F]flortaucipir BPND in MCI/AD patients (BPND100%=0.27±0.15) compared to CN (BPND100%= 0.07±0.13) and all methods showed comparable discriminative effects (AUC100%=0.85[CI=0.78-0.93]; AUC50%HDH=0.84[CI=0.74-0.92]; AUC40%HDH=0.83[CI=0.74-0.92]). Across groups, higher [18F]flortaucipir BPND was related to lower scores on MMSE (standardized ß100%=-0.38[CI=-0.57-0.20]; ß50%HDH= -0.37[CI=-0.54-0.19]; ß40%HDH=-0.35[CI=-0.53-0.17], all p<0.001) and delayed recall (standardized ß100%=-0.64[CI=-0.79-0.49]; ß50%HDH= -0.61[CI=-0.76-0.46]; ß40%HDH=-0.59[CI=-0.75-0.44]; all p<0.001), with comparable effect sizes for all hippocampal VOIs. CONCLUSIONS: Hippocampal tau load measured with [18F]flortaucipir PET is strongly associated with cognitive function. Both discrimination between diagnostic groups and associations between hippocampal [18F]flortaucipir BPND and memory were comparable for all methods. The non-optimized 100% hippocampal VOI may be sufficient for clinical interpretation. However, proper correction for choroid plexus spillover and may be required in case of smaller effect sizes between subject groups or for longitudinal studies.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Carbolinas/farmacocinética , Plexo Corióideo/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Hipocampo/diagnóstico por imagem , Neuroimagem/normas , Tomografia por Emissão de Pósitrons/normas , Proteínas tau/metabolismo , Idoso , Doença de Alzheimer/metabolismo , Doença de Alzheimer/fisiopatologia , Disfunção Cognitiva/metabolismo , Disfunção Cognitiva/fisiopatologia , Feminino , Hipocampo/metabolismo , Hipocampo/fisiopatologia , Humanos , Masculino , Testes de Memória e Aprendizagem , Testes de Estado Mental e Demência , Pessoa de Meia-Idade , Neuroimagem/métodos , Tomografia por Emissão de Pósitrons/métodos
8.
J Cereb Blood Flow Metab ; 39(11): 2172-2180, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-29897009

RESUMO

Accumulation of amyloid beta can be visualized using [18F]florbetapir positron emission tomography. The aim of this study was to identify the optimal model for quantifying [18F]florbetapir uptake and to assess test-retest reliability of corresponding outcome measures. Eight Alzheimer's disease patients (age: 67 ± 6 years, Mini-Mental State Examination (MMSE): 23 ± 3) and eight controls (age: 63 ± 4 years, MMSE: 30 ± 0) were included. Ninety-minute dynamic positron emission tomography scans, together with arterial blood sampling, were acquired immediately following a bolus injection of 294 ± 32 MBq [18F]florbetapir. Several plasma input models and the simplified reference tissue model (SRTM) were evaluated. The Akaike information criterion was used to identify the preferred kinetic model. Compared to controls, Alzheimer's disease patients had lower MMSE scores and evidence for cortical Aß pathology. A reversible two-tissue compartment model with fitted blood volume fraction (2T4k_VB) was the preferred model for describing [18F]florbetapir kinetics. SRTM-derived non-displaceable binding potential (BPND) correlated well (r2 = 0.83, slope = 0.86) with plasma input-derived distribution volume ratio. Test-retest reliability for plasma input-derived distribution volume ratio, SRTM-derived BPND and SUVr(50-70) were r = 0.88, r = 0.91 and r = 0.86, respectively. In vivo kinetics of [18F]florbetapir could best be described by a reversible two-tissue compartmental model and [18F]florbetapir BPND can be reliably estimated using an SRTM.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Compostos de Anilina/análise , Etilenoglicóis/análise , Tomografia por Emissão de Pósitrons/métodos , Idoso , Peptídeos beta-Amiloides/análise , Estudos de Casos e Controles , Feminino , Radioisótopos de Flúor , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes
9.
J Cereb Blood Flow Metab ; 39(1): 163-172, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-28901822

RESUMO

Quantification of regional cerebral blood flow (CBF) using [15O]H2O positron emission tomography (PET) requires the use of an arterial input function. Arterial sampling, however, is not always possible, for example in ill-conditioned or paediatric patients. Therefore, it is of interest to explore the use of non-invasive methods for the quantification of CBF. For validation of non-invasive methods, test-retest normal and hypercapnia data from 15 healthy volunteers were used. For each subject, the data consisted of up to five dynamic [15O]H2O brain PET studies of 10 min and including arterial sampling. A measure of CBF was estimated using several non-invasive methods earlier reported in literature. In addition, various parameters were derived from the time-activity curve (TAC). Performance of these methods was assessed by comparison with full kinetic analysis using correlation and agreement analysis. The analysis was repeated with normalization to the whole brain grey matter value, providing relative CBF distributions. A reliable, absolute quantitative estimate of CBF could not be obtained with the reported non-invasive methods. Relative (normalized) CBF was best estimated using the double integration method.


Assuntos
Circulação Cerebrovascular/fisiologia , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Algoritmos , Artérias Cerebrais/diagnóstico por imagem , Criança , Simulação por Computador , Feminino , Substância Cinzenta/irrigação sanguínea , Substância Cinzenta/diagnóstico por imagem , Humanos , Cinética , Imageamento por Ressonância Magnética , Masculino , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/fisiopatologia , Tomografia por Emissão de Pósitrons , Reprodutibilidade dos Testes , Água
10.
Mult Scler ; 24(4): 543-545, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28443358

RESUMO

Previous studies have demonstrated that the chimeric monoclonal antibody rituximab significantly reduces clinical and radiological disease activity in relapsing-remitting multiple sclerosis as early as 4 weeks after the first administration. The exact mechanisms leading to this rapid effect have not yet been clarified. The aim of this positron emission tomography study was to assess central nervous system penetration as a possible explanation, using zirconium-89-labelled rituximab. No evidence was found for cerebral penetration of [89Zr]rituximab.


Assuntos
Linfócitos B/efeitos dos fármacos , Esclerose Múltipla/tratamento farmacológico , Radioisótopos/uso terapêutico , Rituximab/uso terapêutico , Zircônio/uso terapêutico , Anticorpos Monoclonais Murinos/uso terapêutico , Linfócitos B/imunologia , Humanos , Projetos Piloto , Tomografia por Emissão de Pósitrons/métodos
11.
EJNMMI Res ; 3(1): 79, 2013 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-24308868

RESUMO

BACKGROUND: The aim of this randomised pilot study was to investigate the haemodynamic effects measured by oxygen-15 positron emission tomography (PET) of interventional treatment consisting of either endarterectomy or endovascular treatment of stenosed cerebropetal arteries, or tapering of antihypertensive medication in comparison with standard medical treatment alone in patients with symptomatic internal carotid artery (ICA) occlusion. METHODS: Twenty-three patients with symptomatic ICA occlusion underwent PET scanning at baseline and after 3 months. Twelve patients were randomised to intervention (either endarterectomy or endovascular treatment of stenosed cerebropetal arteries, or tapering of antihypertensive medication) and 11 to standard medical treatment alone. Primary outcome was a change in cerebral blood flow (CBF), cerebral blood volume (CBV) and/or oxygen extraction fraction (OEF) after 3 months measured by PET. RESULTS: There were no differences in changes in CBF, CBV or OEF between the two groups. Only patients with compromised perfusion at presentation showed a borderline significant increase in CBF of 2.8 mL/min/100 mL (95% confidence interval 0.0 to 5.7) after intervention (n = 7). CONCLUSION: This pilot study shows that in patients with symptomatic ICA occlusion, oxygen-15 PET did not detect differences in improvement of CBF, CBV or OEF between interventional and standard treatment.

12.
Alzheimers Res Ther ; 5(4): 36, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23953396

RESUMO

The possibility to map amyloid-beta, the Alzheimer's disease hallmark protein, in vivo opens the application for amyloid imaging in clinical trials with disease-modifying agents. Monitoring change in amyloid burden, particularly when potential amyloid-lowering drugs are at play, requires accurate analytical methods. Studies to date have used suboptimal methods that do not account for heterogeneous changes in flow associated with disease progression and potentially with anti-amyloid drugs. In this commentary, we discuss practical and methodological issues regarding longitudinal amyloid imaging and propose several quantitative, yet feasible, alternatives for reliable assessment of changes over time in amyloid burden.

13.
EJNMMI Res ; 2(1): 57, 2012 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-23067778

RESUMO

BACKGROUND: P-glycoprotein is a blood-brain barrier efflux transporter involved in the clearance of amyloid-beta from the brain and, as such, might be involved in the pathogenesis of Alzheimer's disease. P-glycoprotein is encoded by the highly polymorphic ABCB1 gene. Single-nucleotide polymorphisms in the ABCB1 gene have been associated with altered P-glycoprotein expression and function. P-glycoprotein function at the blood-brain barrier can be quantified in vivo using the P-glycoprotein substrate tracer (R)-[11C]verapamil and positron emission tomography (PET). The purpose of this study was to assess the effects of C1236T, G2677T/A and C3435T single-nucleotide polymorphisms in ABCB1 on blood-brain barrier P-glycoprotein function in healthy subjects and patients with Alzheimer's disease. METHODS: Thirty-two healthy subjects and seventeen patients with Alzheimer's disease underwent 60-min dynamic (R)-[11C]verapamil PET scans. The binding potential of (R)-[11C]verapamil was assessed using a previously validated constrained two-tissue plasma input compartment model and used as outcome measure. DNA was isolated from frozen blood samples and C1236T, G2677T/A and C3435T single-nucleotide polymorphisms were amplified by polymerase chain reaction. RESULTS: In healthy controls, binding potential did not differ between subjects without and with one or more T present in C1236T, G2677T and C3435T. In contrast, patients with Alzheimer's disease with one or more T in C1236T, G2677T and C3435T had significantly higher binding potential values than patients without a T. In addition, there was a relationship between binding potential and T dose in C1236T and G2677T. CONCLUSIONS: In Alzheimer's disease patients, C1236T, G2677T/A and C3435T single-nucleotide polymorphisms may be related to changes in P-glycoprotein function at the blood-brain barrier. As such, genetic variations in ABCB1 might contribute to the progression of amyloid-beta deposition in the brain.

14.
EJNMMI Res ; 2(1): 1, 2012 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-22251281

RESUMO

BACKGROUND: P-glycoprotein [Pgp] dysfunction may be involved in neurodegenerative diseases, such as Alzheimer's disease, and in drug resistant epilepsy. Positron emission tomography using the Pgp substrate tracer (R)-[11C]verapamil enables in vivo quantification of Pgp function at the human blood-brain barrier. Knowledge of test-retest variability is important for assessing changes over time or after treatment with disease-modifying drugs. The purpose of this study was to assess reproducibility of several tracer kinetic models used for analysis of (R)-[11C]verapamil data. METHODS: Dynamic (R)-[11C]verapamil scans with arterial sampling were performed twice on the same day in 13 healthy controls. Data were reconstructed using both filtered back projection [FBP] and partial volume corrected ordered subset expectation maximization [PVC OSEM]. All data were analysed using single-tissue and two-tissue compartment models. Global and regional test-retest variability was determined for various outcome measures. RESULTS: Analysis using the Akaike information criterion showed that a constrained two-tissue compartment model provided the best fits to the data. Global test-retest variability of the volume of distribution was comparable for single-tissue (6%) and constrained two-tissue (9%) compartment models. Using a single-tissue compartment model covering the first 10 min of data yielded acceptable global test-retest variability (9%) for the outcome measure K1. Test-retest variability of binding potential derived from the constrained two-tissue compartment model was less robust, but still acceptable (22%). Test-retest variability was comparable for PVC OSEM and FBP reconstructed data. CONCLUSION: The model of choice for analysing (R)-[11C]verapamil data is a constrained two-tissue compartment model.

15.
Alzheimers Res Ther ; 3(5): 26, 2011 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-21936965

RESUMO

Patients with mild cognitive impairment are at an increased risk of progression to Alzheimer's disease. However, not all patients with mild cognitive impairment progress, and it is difficult to accurately identify those patients who are in the prodromal stage of Alzheimer's disease. In a recent paper, Koivunen and colleagues report that Pittsburgh compound-B, an amyloid-beta positron emission tomography ligand, predicts the progression of patients with mild cognitive impairment to Alzheimer's disease. Of 29 subjects with mild cognitive impairment, 21 (72%) had a positive Pittsburgh compound-B positron emission tomography baseline scan. In their study, 15 of these 21 (71%) patients progressed to Alzheimer's disease, whilst only 1 out of 8 (12.5%) Pittsburgh compound-B-negative patients with mild cognitive impairment did so. Moreover, in these mild cognitive impairment patients, the overall amyloid burden increased approximately 2.5% during the follow-up period. This is consistent with other longitudinal amyloid imaging studies that found a similar increase in amyloid deposition over time in patients with mild cognitive impairment. These studies together challenge current theories that propose a flattening of the increase of brain amyloid deposition already in the preclinical stage of Alzheimer's disease. These findings may have important implications for the design of future clinical trials aimed at preventing progression to Alzheimer's disease by lowering the brain amyloid-beta burden in patients with mild cognitive impairment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...